In many instances, it is inconvenient to install a weir or other flow measuring device to determine the massflow rate of white water or thin stock. In such a case, the mass flow rate may be found by introducing a knownsolution of a salt, such as sodium thiosulfate, into the stream. By determining the dilution of the salt in the unknown stream, the mass flow rate may be calculated with reasonable accuracy.
Product Details
Published: 2017 Number of Pages: 3 File Size: 1 file , 110 KB