ASTM F1977-04(2017) Standard Test Method for Determining Initial, Fractional, Filtration Efficiency of a Vacuum Cleaner System

standard by ASTM International, 03/01/2017

More details

In stock

$23.40

-55%

$52.00

More info

Full Description

1.1This test method may be used to determine the initial, fractional, filtration efficiency of household and commercial canister (tank-type), stick, hand-held, upright, and utility vacuum cleaner systems.

1.1.1Water-filtration vacuum cleaners which do not utilize a replaceable dry media filter located between the water-based filter and cleaning air exhaust are not included in this test method. It has been determined that the exhaust of these vacuum cleaners is not compatible with the specified discrete particle counter (DPC) procedure.

1.2The initial, fractional, filtration efficiencies of the entire vacuum cleaner system, at six discrete particle sizes (0.3, 0.5, 0.7, 1.0, 2.0, and 3 m), is derived by counting upstream challenge particles and the constituent of downstream particles while the vacuum cleaner system is being operated in a stationary test condition.

1.3The vacuum cleaner system is tested at the nozzle with the normal airflow rate produced by restricting the inlet to the nozzle adapter with the 11/4-in. orifice.

1.4The vacuum cleaner system is tested with a new filter(s) installed, and with no preliminary dust loading. The fractional efficiencies determined by this test method shall be considered initial system filtration efficiencies. The filters are not changed between test runs on the same cleaner.

1.5Neutralized potassium chloride (KCl) is used as the challenge media in this test method.

1.6One or two particle counters may be used to satisfy the requirements of this test method. If using one counter, flow control is required to switch between sampling the upstream and downstream air sampling probes.

1.7To efficiently utilize this test method, automated test equipment and computer automation is recommended.

1.8Different sampling parameters, flow rates, and so forth, for the specific applications of the equipment and test procedure may provide equivalent results. It is beyond the scope of this test method to define those various possibilities.

1.9This test method is limited to the test apparatus, or its equivalent, as described in this document.

1.10This test method is not intended or designed to provide any measure of the health effects or medical aspects of vacuum cleaning.

1.11This test method is not intended or designed to determine the integrity of HEPA filtration assemblies used in vacuum cleaner systems employed in nuclear and defense facilities.

1.12The inch-pound system of units is used in this test method, except for the common usage of the micrometer, m, for the description of particle size which is a SI unit.

1.13This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.