ASTM D4105/D4105M-20 Standard Practice for (Analytical Procedure) for Determining Transmissivity and Storage Coefficient of Nonleaky Confined Aquifers by the Modified Theis Nonequilibrium Method

standard by ASTM International, 05/15/2020

More details

In stock

$23.40

-55%

$52.00

More info

Full Description

1.1This practice covers an analytical procedure for determining transmissivity and storage coefficient of a nonleaky confined aquifer under conditions of radial flow to a fully penetrating well of constant flux. This practice is a shortcut procedure used to apply the Theis nonequilibrium method. The Theis method is described in Practice D4106.

1.2This practice, along with others, is used in conjunction with the field procedure given in Test Method D4050.

1.3Limitations-The limitations of this practice are primarily related to the correspondence between the field situation and the simplifying assumptions of this practice (see 5.1). Furthermore, application is valid only for values of uless than 0.01 (uis defined in Eq 2, in 8.6).

1.4All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026.

1.4.1The procedures used to specify how data are collected/recorded or calculated, in this standard are regarded as the industry standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the users objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. It is beyond the scope of this standard to consider significant digits used in analytical methods for engineering design.

1.5Units-The values stated in either SI Units or inch-pound units are to be regarded separately as standard. The values in each system may not be exact equivalents; therefore each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. Reporting of results in units other than SI shall not be regarded as nonconformance with this practice.

1.6This practice offers a set of instructions for performing one or more specific operations. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of the practice may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without the consideration of a projects many unique aspects. The word Standard in the title of this document means only that the document has been approved through the ASTM consensus process.

1.7This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.8This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.